Website
Hosting
Holden
Dynamics has over 25 years of practical "hands on"
experience
with Computers and related systems. We were pioneers in introducing
the Internet to Australians
We
now provide 2 options of Webhosting:
Both provide state-of-the-art service and reliability, 24/7
technical back-up and support.
To answer an often asked question, we have as much control and
responsibility over one as the other - we (like other companies)
are resellers/aggregators of their services to meet the needs
of our customers. All contact with the hosting companies takes
place via telephone, fax or email - so physical proximity is
not an issue. The criteria for judging is therefore reliability,
speed and cost. We have found both providers equally reliable
with ample speed.
The decision for customers comes down to:
1. cost and
2. comfortability with your site being hosted outside Australia
The
choice is yours !
1.
Webcentral - Australia's largest hosting company.
"Economy" webhosting package, suitable for most small
to medium busineses. Includes email.
Annual cost: $420.00 ($381.82 plus GST)
Initial
set-up: $64.00
2.
Introducing our own Holden Dynamics Hosting Service
utilising a North American provider.
Our "standard" package is also suitable for most small
to medium busineses. Includes email.
Annual cost: $198 ($180 plus GST)
Initial set-up: $35.00
Our
servers are located in the USA, in a major datacentre with high
speed links into Australia and, of course, the rest of the world
via the massive US internal and external internet structure.
Test
a website hosted on our US server click on www.Holden.net.au
| |
|
| |
Overview
of our US Datacentre |
| |
| |
The
Data Hosting Centre we utilise owns and operates two state-of-the-art
data centers in secure locations in the US, offering complete
redundancy in power, HVAC, fire suppression, network connectivity,
and security. With over 53,000 sq ft of raised floor between
the two facilities, their datacenter facility sits atop
multiple power grids driven by TXU electric, with PowerWare
UPS battery backup power and dual diesel generators onsite.
Their HVAC systems are condenser units by Data Aire to
provide redundancy in cooling coupled with ten managed
backbone providers. Twelve more third party backbone providers
are available in their buildings via cross connect. Fire
suppression includes a pre-action dry pipe system including
VESDA (Very Early Smoke Detection Apparatus) with over
700 smoke detectors between the two facilities. |
| |
Details
of facility No. 1 |
| |
|
| |
|
- 60,000
sq. ft. facility
- 35,000
sq. ft. of raised floor
- (21)
26-ton Data Air AC units
- Very
Early Smoke Detection Apparatus (VESDA)
- Pre-action
dry pipe sprinkler system
- Over
500 smoke detectors in an integrated system
- Simplex
security badge entry/exit on all doors to
facility
|
- Multiple
TXU electrical grids
- 4800
amps of 480v input power
- 3
main transfer switches
- (6)
500KVA Powerware UPS units with 90 batteries
per unit
- Standalone
PDUs at each cabinet row
- 1-megawatt
generator (2000-gallon tank)
- 1.5-megawatt
generator (2200-gallon tank)
- DataTrax
monitoring software for all data center infrastructure
|
|
| |
 |
| |
|
| |
Network
Infrastructure |
| |
| |
The
Data Centre network architecture utilises the Enterprise
routing and switching engines from Juniper and Cisco.
They utilise Juniper M20 routers as border routers, Cisco
6500 series switches in our distribution layer and Cisco
6500 switches in our aggregation layers, and Cisco 3500
and 2900 series switches at the customer layer. Their
network is fully meshed and redundant with 11 backbone
providers. |
| |
|
|
- Cisco
Certified Network
- Cisco
6500 series distribution routing switched
- Cisco
6500 series aggregation switches for customer
access
- Juniper
M20 border routers
- 100%
uptime SLA utilizing HSRP/BGP
|
- OC48
SONET Ring - SBC
- OC48
SONET Ring - Time Warner
- OC48
SONET Ring - XO Communications
- OC48
SONET Ring - MCI
- OC48
SONET Ring - Looking Glass
- OC48
SONET Ring - Broadwing
|
|
| |
|
|
- 3
Gbps Direct Fiber - AboveNet
- 3
Gbps Direct Fiber - AT&T
- 1
Gbps Direct Fiber - Broadwing
- 1
Gbps Direct Fiber - Dallas Public Peering
- 1
Gbps Direct Fiber - Global Crossing
- 3
Gbps Direct Fiber - Level3
- 1
Gbps Direct Fiber - nLayer
- 2
Gbps Direct Fiber - Sprint
- 1
Gbps Direct Fiber - Time Warner
- 1
Gbps Direct Fiber - UUNET
- 1
Gbps Direct Fiber - Verio
|
- T3
and T1 Access - EPGN
- T3
and T1 Access - SBC
- T3
and T1 Access - Time Warner
- T3
and T1 Access - XO Communications
- T3
and T1 Access - MCI
|
|
| |
 |
| |
|
| |
At-A-Glance
Network Overview |
| |
| |
 |
| |
| |
|
| Details
of facility No. 2 |
| |
|
- 22,000
sq. ft. facility
- 18,000
sq. ft. of raised floor
- (12)
26-ton Data Air AC units
- Very
Early Smoke Detection Apparatus (VESDA)
- Pre-action
dry pipe sprinkler system
- Over
220 smoke detectors in an integrated system
- Simplex
security badge entry/exit on all doors to facility
|
-
TXU fault tolerant electrical grid
- 2000
amps of 480v input power
- 1
main transfer switch
- (2)
500KVA Powerware UPS units with 90 batteries per unit
- Standalone
PDUs at each cabinet row
- 1.5-megawatt
generator (2200-gallon tank)
- DataTrax
monitoring software for all data center infrastructure
|

|
 |